Pinal County, AZCompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Backflow review queue

Backflow assembly test · 425 Hickory Rd

Approved

Filed Jan 16, 2026 by Riley Pruitt, Heritage Plumbing & Backflow · filed from phone

Report

Date of service
Jan 16, 2026
Assembly type
RP
Serial number
B140119
Size
1
Test gauge serial
G-9632
Gauge calibration date
Aug 30, 2025
Check valve 1
5.1 psid
Check valve 1 closed tight
Yes
Check valve 2
2 psid
Relief valve opened at
3.7 psid
Result
Pass
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for backflow tester
  • All required fields present
  • Address matches parcel 021-49-01180
  • Readings in range, no flags
  • Result: passing. Next due date resets when approved.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

425 Hickory Rd
Owner: Avery Brandt
Parcel 021-49-01180