Septic maintenance (pump-out) · 3365 Meadow Lark Trl

Approved

Filed Nov 14, 2026 by Avery Nguyen, Northstar Septic Service · filed from phone

Report

Date of service
Nov 14, 2026
Tank size
1500 gal
Compartments
1
Gallons pumped
1369 gal
Sludge depth
34 in
Scum depth
6 in
Baffles in good condition
Yes
Effluent filter
None present
Lids and risers secure
No
Disposal site
County treatment plant
Repair needed
Yes
Repair needed: describe
Outlet baffle missing
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 013-36-01352
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Unsecured lids are a safety hazard.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

3365 Meadow Lark Trl
Owner: Morgan Stroud
Parcel 013-36-01352