← Septic review queue
Septic maintenance (pump-out) · 4171 Sycamore Ct
ApprovedFiled Jan 20, 2024 by Cameron Kessler, Evergreen Wastewater · filed from phone
Report
- Date of service
- Jan 20, 2024
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 854 gal
- Sludge depth
- 33 in
- Scum depth
- 9 in
- Baffles in good condition
- Yes
- Effluent filter
- Cleaned
- Lids and risers secure
- No
- Disposal site
- County treatment plant
- Repair needed
- Yes
- Repair needed: describe
- Distribution box settled
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 041-69-01120
- Sludge is over a third of a typical tank depth; check for system failure.
- Unsecured lids are a safety hazard.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by Auto-approved (no flags). The property's next due date is set and the owner gets a receipt.
Property
4171 Sycamore Ct
Owner: Quinn Hollins
Parcel 041-69-01120