← Septic review queue
Septic maintenance (pump-out) · 1811 Pine Knoll Trl
ApprovedFiled Sep 5, 2024 by Shawn Wexler, Clearwater Septic Service · filed from phone
Report
- Date of service
- Sep 5, 2024
- Tank size
- 1500 gal
- Compartments
- 1
- Gallons pumped
- 1508 gal
- Sludge depth
- 14 in
- Scum depth
- 5 in
- Baffles in good condition
- Yes
- Effluent filter
- Cleaned
- Lids and risers secure
- Yes
- Disposal site
- Permitted land-application site
- Repair needed
- No
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 057-48-01230
- Readings in range, no flags
- Result: passing. Next due date resets when approved.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
1811 Pine Knoll Trl
Owner: Avery Kessler
Parcel 057-48-01230