← Septic review queue
Septic maintenance (pump-out) · 1258 Ridgeview Rd
ApprovedFiled Dec 11, 2023 by Quinn Danner, Valley Wastewater · paper form read in and confirmed by staff
Report
- Date of service
- Dec 11, 2023
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 895 gal
- Sludge depth
- 25 in
- Scum depth
- 8 in
- Baffles in good condition
- No
- Effluent filter
- None present
- Lids and risers secure
- No
- Disposal site
- Regional wastewater plant
- Repair needed
- Yes
- Repair needed: describe
- Outlet baffle missing
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 069-29-01265
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- Unsecured lids are a safety hazard.
- No photos attached.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
1258 Ridgeview Rd
Owner: Parker Brandt
Parcel 069-29-01265