San Diego County, CACompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 7401 Laurel Dr

Approved

Filed Mar 23, 2022 by Alex Pruitt, Summit Septic Service · filed from phone

Report

Date of service
Mar 23, 2022
Tank size
1000 gal
Compartments
2
Gallons pumped
1011 gal
Sludge depth
29 in
Scum depth
7 in
Baffles in good condition
No
Effluent filter
Replaced
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 073-10-01191
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

7401 Laurel Dr
Owner: Jamie Nguyen
Parcel 073-10-01191