Septic maintenance (pump-out) · 3506 Quarry Way

Approved

Filed Jun 20, 2017 by Riley Calloway, Heritage Septic Service · filed from phone

Report

Date of service
Jun 20, 2017
Tank size
750 gal
Compartments
1
Gallons pumped
771 gal
Sludge depth
30 in
Scum depth
8 in
Baffles in good condition
Yes
Effluent filter
Replaced
Lids and risers secure
Yes
Disposal site
County treatment plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 083-59-01113
  • Sludge is over a third of a typical tank depth; check for system failure.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

3506 Quarry Way
Owner: Quinn Ramirez
Parcel 083-59-01113