Septic maintenance (pump-out) · 853 Old Church Way

Approved

Filed Jul 14, 2026 by Sam Nguyen, Lakeside Wastewater · filed from phone

Report

Date of service
Jul 14, 2026
Tank size
750 gal
Compartments
2
Gallons pumped
779 gal
Sludge depth
26 in
Scum depth
7 in
Baffles in good condition
Yes
Effluent filter
None present
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 021-34-01256
  • Sludge is over a third of a typical tank depth; check for system failure.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

853 Old Church Way
Owner: Jordan Hollins
Parcel 021-34-01256