Back to the septic review queue
Septic maintenance (pump-out): 1362 Hickory Way
ApprovedFiled Dec 20, 2020 by Parker Nguyen, Valley Pumping Co. Filed from a phone.
Report
- Date of service
- Dec 20, 2020
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 918 gal
- Sludge depth
- 34 in
- Scum depth
- 6 in
- Baffles in good condition
- No
- Effluent filter
- Cleaned
- Lids and risers secure
- No
- Disposal site
- Permitted land-application site
- Repair needed
- No
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Parker Nguyen, current on the service date
- All required fields present
- Address matches parcel 023-59-01245
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- Unsecured lids are a safety hazard.
- Result: passing. Next due date resets when approved.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
1362 Hickory Way
Owner: Cameron Ramirez
Parcel 023-59-01245