Back to the septic review queue

Septic maintenance (pump-out): 2051 Laurel Ln

Approved

Filed Apr 1, 2022 by Parker Fairley, Ridge Wastewater. Filed from a phone.

Report

Date of service
Apr 1, 2022
Tank size
1250 gal
Compartments
1
Gallons pumped
1081 gal
Sludge depth
31 in
Scum depth
7 in
Baffles in good condition
Yes
Effluent filter
None present
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Parker Fairley, current on the service date
  • All required fields present
  • Address matches parcel 057-77-01051
  • Sludge is over a third of a typical tank depth; check for system failure.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

2051 Laurel Ln
Owner: Morgan Whitcomb
Parcel 057-77-01051