← Septic review queue
Septic maintenance (pump-out) · 5119 Orchard Trl
ApprovedFiled May 28, 2019 by Sam Okafor, Ridge Wastewater · filed from phone
Report
- Date of service
- May 28, 2019
- Tank size
- 1000 gal
- Compartments
- 2
- Gallons pumped
- 958 gal
- Sludge depth
- 25 in
- Scum depth
- 2 in
- Baffles in good condition
- No
- Effluent filter
- None present
- Lids and risers secure
- Yes
- Disposal site
- Regional wastewater plant
- Repair needed
- No
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file and current for septage hauler
- All required fields present
- Address matches parcel 067-36-01071
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- Result: passing. Next due date resets when approved.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
5119 Orchard Trl
Owner: Blake Vance
Parcel 067-36-01071