Montezuma County, COCompliance reporting portal
Demo · made-up dataOpen the pro appChange county
← Septic review queue

Septic maintenance (pump-out) · 8175 Sycamore Trl

Approved

Filed Apr 2, 2022 by Sam Vance, Evergreen Wastewater · paper form read in and confirmed by staff

Report

Date of service
Apr 2, 2022
Tank size
750 gal
Compartments
1
Gallons pumped
661 gal
Sludge depth
27 in
Scum depth
2 in
Baffles in good condition
No
Effluent filter
Cleaned
Lids and risers secure
No
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Outlet baffle missing
Photos
2 attached
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 083-20-01009
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Unsecured lids are a safety hazard.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

8175 Sycamore Trl
Owner: Quinn Nguyen
Parcel 083-20-01009