Septic maintenance (pump-out) · 4974 Sycamore Way

Approved

Filed Mar 19, 2025 by Emerson Benton, Heritage Wastewater · filed from phone

Report

Date of service
Mar 19, 2025
Tank size
750 gal
Compartments
2
Gallons pumped
748 gal
Sludge depth
27 in
Scum depth
6 in
Baffles in good condition
Yes
Effluent filter
Cleaned
Lids and risers secure
No
Disposal site
Regional wastewater plant
Repair needed
No
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file and current for septage hauler
  • All required fields present
  • Address matches parcel 091-44-01324
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Unsecured lids are a safety hazard.
  • No photos attached.
  • Result: passing. Next due date resets when approved.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

4974 Sycamore Way
Owner: Taylor Okafor
Parcel 091-44-01324