Septic maintenance (pump-out) · 7002 Spring Branch Trl

Approved

Filed Oct 16, 2020 by Shawn Stroud, Lakeside Pumping Co · paper form read in and confirmed by staff

Report

Date of service
Oct 16, 2020
Tank size
1250 gal
Compartments
2
Gallons pumped
1224 gal
Sludge depth
24 in
Scum depth
7 in
Baffles in good condition
No
Effluent filter
Cleaned
Lids and risers secure
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Outlet baffle missing
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Shawn Stroud, current on the service date
  • All required fields present
  • Address matches parcel 113-29-01162
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

7002 Spring Branch Trl
Owner: Logan Kessler
Parcel 113-29-01162